X-RAY 2000



Specifications


Field of application insulation and jacketing line
Insulating material PVC, PE, HDPE
measurement of other types of material on request
Insulation thickness ≥ 0,3 – 5 mm
measurement of thicker or smaller wall thickness on request
Calibration the X-RAY 2000 requires no calibration
Sight field 35 mm (recommended for cables with a diameter up to 30 mm)
70 mm (recommended for cables with a diameter up to 70 mm)
120 mm (recommended for cables with a diameter up to 100 mm)
200 mm (recommended for cables with a diameter up to 180 mm)
300 mm (recommended for cables with a diameter up to 270 mm)
Safety (radiation) on-line measurements taken in direct proximity to the measuring head have revealed
that the X-RAY 2000 with its radiation of 2.5 μSv/h is far below
limiting values of all international regulations (7,5 μSv/h)
Measuring accuracy wall thickness/eccentricity better than ±20 μm
Interfaces RS 485 + RS 232 diagnostic interface
Resolution 10 μm
Power supply 230 V AC ± 5 %, 50 – 60 Hz
Power consumption 200 VA
Permissible temperature +5 … +45 °C (+41 … +113 °F)
Dimensions X-RAY 2035 955 mm x 1650 mm x 387 mm (w/h/d)
X-RAY 2060 808 mm x 1172 mm x 385 mm (w/h/d)
X-RAY 2120 1060 mm x 1230 mm x 335 mm (w/h/d)
X-RAY 2200 1312 mm x 1372 mm x 386 mm (w/h/d)
X-RAY 2300 1312 mm x 1372 mm x 386 mm (w/h/d)

 

Model min. / max.
cable diameter
measuring accuracy* sight field opening of the measuring head
X-RAY 2035 5 to   30 mm 5 µm 35 mm 100 mm
X-RAY 2060 6 to   70 mm 10 µm 70 mm 100 mm
X-RAY 2120 10 to 100 mm 10 µm 120 mm 180 mm
X-RAY 2200 20 to   180 mm 20 µm 200 mm 350 mm
X-RAY 2300 30 to 270 mm 30 µm 300 mm 400 mm