| Specifications X-RAY 8000 NXT | |
| Field of application | CCV-, VCV-line operating with nitrogen and /or steam |
| Field of use | medium, high and extra high voltage cable with XLPE, EPR, EPDM, HYPALON insulation etc. |
| Measuring range | 100/160 mm XLPE-tubes, 45 mm EPR-cables* |
| Measuring accuracy |
Wall thickness: ± 15µm, ± 0.02 % |
| Repeatability | Wall thickness 7.5 µm, diameter 3 µm |
| Scan speed | Up to 60 mm/s |
| Radiation | Measurements taken on-line directly at the scanner box have shown that natural radiation, which can be measured in the atmosphere, is not increased by the X-RAY 8000. At any position next to the X-RAY 8000 the radiation which could be measured was below 0.07 µSv/h. |
| Permissible temperature | +5 to +50°C |
| Cooling water consumption | approx. 60l/h at t ≤ 28°C |
| Dimensions | Approx. 560 x 560, 270 mm long |
| Specifications Processor/Monitor-System | |
| Display | TFT-color monitor |
| Display of measured values |
|
| Operation | Touchscreen |
| Control modes |
|
| Control interface | Isolated in- and output, max ± 12 V, max ± 5mA |
| Serial interfaces** | USB, NetDDE, OPC, Ethernet/IP, RS 485 *** |
| Contact outputs | Contact outputs for tolerance or status messages (max. 30 V, max. 0.5 A) |
| Network/Modem interface | Option |
| Data recording | A hard disk stores the measured values in a time or length related interval |
| Power supply | 230 V, 50 to 60 Hz |
| Power consumption | 600 VA |
| Permissible temperature | +5 to +45°C |
| Dimensions (cabinet) | 19" cabinet, 600 x 610 x 2100 mm |
* 70 kV scanners for EPR cable with big diameters
** Option
*** Signal outputs can be provided for the automatic centering of the crosshead
Technical data is subject to change