| Cable dimensions | width: 2........100 mm thickness: 0.25........3 mm |
| Conductor material | copper, tin-plated copper, silver-plated copper |
| Conductor dimensions | width: 0.5........ 25 mm thickness: 0.05....... .1 mm |
| Insulating material | PVC, PE or other plastic materials |
| Measuring accuracy | width measurement: ± 10 μm pitch measurement: ± 10 μm conductor width: ± 10 μm gap width: ± 10 μm gap thickness: ±10 μm edge to edge: ±10 μm (PVC) sheath thickness: ± 10 μm (PVC) (5 μm)2) |
| Scan speed | up to 60 mm/sec. |
| Safety | Radiation measurements by independent experts have revealed that the radiation in direct proximity of the device is far below limiting values of all international regulations. |
| Cooling | water 60 l/h, at a water temperature of 10 to 28° C (+50 … +82° F) |
| Environmental temperature | + 5 to + 45° C (+41 … +113° F) |
| Power supply | 230 V AC +7 /– 15%, 50/60 Hz |